1.配置只讀路由
①配置A副本的只讀路由屬性(ReadOnly代表‘只讀意向’)
ALTER AVAILABILITY GROUP [testAG]
MODIFY REPLICA ON N'WIN-14VNU7CGQO1' WITH (SECONDARY_ROLE (ALLOW_CONNECTIONS = READ_ONLY));
②配置A副本的只讀路由URL
ALTER AVAILABILITY GROUP [testAG]
MODIFY REPLICA ON N'WIN-14VNU7CGQO1' WITH (SECONDARY_ROLE (READ_ONLY_ROUTING_URL = N'tcp://WIN-14VNU7CGQO1.fnst.com:1433'));
③配置B副本的只讀路由屬性
ALTER AVAILABILITY GROUP [testAG]
MODIFY REPLICA ON N'WIN-14VNU7CGQO2' WITH (SECONDARY_ROLE (ALLOW_CONNECTIONS = READ_ONLY));
④配置B副本的只讀路由URL
ALTER AVAILABILITY GROUP [testAG]
MODIFY REPLICA ON N'WIN-14VNU7CGQO2' WITH (SECONDARY_ROLE (READ_ONLY_ROUTING_URL = N'tcp://WIN-14VNU7CGQO2.fnst.com:1433'));
⑤配置A副本作為主副本時候的只讀路由表
ALTER AVAILABILITY GROUP [testAG]
MODIFY REPLICA ON N'WIN-14VNU7CGQO1' WITH (PRIMARY_ROLE (READ_ONLY_ROUTING_LIST=('WIN-14VNU7CGQO2','WIN-14VNU7CGQO1')));
⑥配置B副本作為主副本時候的只讀路由表
ALTER AVAILABILITY GROUP [testAG]
MODIFY REPLICA ON N'WIN-14VNU7CGQO2' WITH (PRIMARY_ROLE (READ_ONLY_ROUTING_LIST=('WIN-14VNU7CGQO1','WIN-14VNU7CGQO2')));
配置完成後:使用 SELECT * FROM sys.availability_read_only_routing_lists 查看路由表

確認一下應該是下面的形式 :
A B
A A
B A
B B
為什麼這麼配置請分析如下過程
1.正常運行時候,A作為主副本,B作為輔助副本,客戶端連接字符串指定數據源是偵聽器地址
2.此時發送只讀請求
3.偵聽器收到只讀數據請求,有主副本A來處理,主副本A發現是ReadOnly,就查詢路由表,發現第一條符合,就把只讀請求交給輔助副本B來處理
4.此時主副本A失效了,那麼由AlwaysOn的高可用可知,會讓輔助B作為了主副本,等原來的主副本A恢復之後,讓A成為新的輔助副本(當然這些對客戶端是透明的)
5.副本A恢復之後,再發送一條只讀請求
6.此時偵聽器使用主副本B來處理這個請求,如果不像上面的設置方法,就找不到B到A的路由,也就不能實現所謂的高可用
2.配置的確認
例如:有一個可用組testAG,其中有兩個副本A和B,其中主副本為A,輔助副本為B,並且在AlwaysOn可用組內設定了Listener

A和B的配置如下:
3.測試只讀路由
客戶端程序中指定連接字符串:connectStr = "Data Source=tcp:193.160.26.30,1433;Initial Catalog=test;Integrated Security=True;ApplicationIntent=ReadOnly;MultiSubnetFailover=True";
重要參數說明:
DataSource:tcp:193.160.26.30,1433 這個填寫的是偵聽器的地址
ApplicationIntent=ReadOnly 說明這個連接是一個只讀意向的連接,這樣的情況下,請求發送到主副本A上,主副本發現是隻讀的請求會先產看只讀路由表,然後通過
主副本A轉發到輔助副本B上
會出現的問題: 如果客戶端這時候的連接字符串指定了ApplicationIntent=ReadOnly,它只表明這是一個只讀意向的請求,但是不能保證請求一點是隻讀的,如果是寫請求
就會出現失敗的情況。所以在進行寫操作的時候不能設置這個選項。
測試程序如下:
主副本: 192.168.24.28
輔助副本:192.168.24.32
偵聽器:192.168.24.30:1433
代碼如下:
namespace AlwaysonTest
{
public partial class Form1 : Form
{
public Form1()
{
InitializeComponent();
Control.CheckForIllegalCrossThreadCalls = false;
}
private void btnInsert_Click(object sender, EventArgs e)
{
Thread t = new Thread(Write);
t.IsBackground = true;
t.Start();
}
private void btnReadData_Click(object sender, EventArgs e)
{
Thread t = new Thread(Read);
t.IsBackground = true;
t.Start();
}
public void Write()
{
string name = System.DateTime.Now.ToString();
//插入數據的時候,連接字符串不指定ReadOnly
string connectStrW = "Data Source=tcp:193.160.26.30,1433;Initial Catalog=test;Integrated Security=True;MultiSubnetFailover=True";
int count = Convert.ToInt32(textBox4.Text);
using (SqlConnection conn = new SqlConnection(connectStrW))
{
for (var i = 1; i <= count; i++)
{
conn.Open();//打開數據庫
//創建數據庫命令
SqlCommand cmd = conn.CreateCommand();
//創建查詢語句 在寫的操作過程中,寫之前先讀操作,測試不加ReadOnly時候只讀路由有沒有效果
cmd.CommandText = "select count(*) from test1";
int x = (int)cmd.ExecuteScalar();
//創建查詢語句
Thread.Sleep(1000);
cmd.CommandText = "Insert into test1 values" + '(' + '\\'' + name + '\\'' + ')';
cmd.ExecuteNonQuery();
textBox1.Text = (x + i).ToString();
conn.Close();
}
}
}
public void Read()
{ //查詢數據的時候,連接字符串指定ReadOnly
string connectStr = "Data Source=tcp:193.160.26.30,1433;Initial Catalog=test;Integrated Security=True;ApplicationIntent=ReadOnly;MultiSubnetFailover=True";
int count = Convert.ToInt32(textBox4.Text);
for (var j = 0; j <= count; j++)
{
Thread.Sleep(1000);
using (SqlConnection conn = new SqlConnection(connectStr))
{
conn.Open();//打開數據庫
//創建數據庫命令
SqlCommand cmd = conn.CreateCommand();
//創建查詢語句
cmd.CommandText = "select count(*) from test1";
int x = (int)cmd.ExecuteScalar();
textBox2.Text = x.ToString();
conn.Close();
}
}
}
}
}
檢測結果:
開始之前,打開Sql Server Profiler進行數據的分析。
如下圖所示,為了排除干擾,發現程序執行前是沒有數據的讀寫的。
測試點一: 寫操作不加ReadOnly限制,是不是能夠在主副本寫成功
結果如下圖,
結論:因為只有主副本有操作記錄,可以說明是在主副本進行寫入成功的
測試點二:讀操作加上ReadOnly限制,它的處理副本是主副本還是輔助副本(清除上次記錄)
結果如下圖:
結論:左側主副本的內容和我們的查詢內容無關,右側輔助副本全部都是我們的查詢操作,所以可以證明存在ReadOnly的時候讀操作都被輔助副本執行
測試點三:讀操作不加ReadOnly限制,它的處理副本是主副本還是輔助副本
Read()操作中連接字符串去掉ApplicationIntent=ReadOnly,並清空上面操作信息,然後執行程序
結論:在不加ReadOnly選項的時候,讀操作全部有主副本進行了處理
測試點四:寫操作加上ReadOnly限制,能夠被主副本進行處理
在Write()中連接字符串中加上ApplicationIntent=ReadOnly,清空上面操作記錄,執行程序
結論:上圖可以知道,在寫操作的時候,如果有ReadOnly會報錯
閱讀更多 信息安全攻與防 的文章